Input Specifications   
Voltage Range See table below
Frequency Range (60Hz) 57-63 Hz
(50Hz) 47-53 Hz
Surge Protection Meets ANSI C62.41, Category A & B
EN 50091-2 and EN50082-2
Power Factor Powerware 9315 200-250kVA and Powerware 9315 300-400kVA: 0.95 typical at full load with optional input filter. Input current distortion less than 7% typically with optional filter

Powerware 9315 500-625kVA: 0.85 lag at nominal full load; 0.9 lag with input filter. Less than 12% without input filter, less than 5% with optional input filter
Output Specifications
Voltage Regulation Better than +/- 1%
Voltage THD (linear load): less than 3% for a 100%
(linear load): 2% for a single harmonic
(non-linear load): less than 5% when tested in accordance with EN50091-3
Transient Response Less than 5% for 100% load step; full recovery within 1 cycle
Frequency (Free Run) +/- 0.005 Hz
Frequency Sync Range +/- 0.5 Hz
Frequency Slew Rate 1 Hz/second maximum
Voltage adjustment range (operator) +/- 0.5%
Environment Specifications
Ambient temperature 0C to 40C
Storage -20C to +70C
Relative Humidity 5-95% non-condensing
Altitude 1500 meters (5000ft.) at 40°C ambient temperature without loading derating
Audible noise At 1 meter; in accordance with ISO 7779
Powerware 9315 200-250kVA: Less than 65 dBA
Powerware 9315 300-400kVA: Less than 72 dBA
Powerware 9315 500-625kVA: Less than 75 dBA
Electrostatic discharge Withstands 25kV without damage or disturbance to the load; exceeds requirements of IEC 801-2 EMC
EMC Meets FCC Class A and EN 50091-2 (CISPR 22, Class A)
Battery Specifications
Matching cabinets Remote option available
Battery Type Sealed, valve-regulated lead acid
Recharge time 10 -12 times the discharge time to 95%
Other battery options Wet cell and nickel-cadmium, batteries; open racks available
Safety
Safety UL 1778 Listed
CUL CAN/CSA C22.2 NO.107.1 Listed, EN 50091-1

All Cabinets provide seismic mounting features
Selectable DC ground fault detection capability

Model Selection Guide

  Model 200 Model 250 Model 300 Model 400 Model 500 Model 625
   200 kVA
/160 kW
250 kVA
/200 kW
300 kVA
/240 kW
300 kVA
/270 kW
400 kVA
/320 kW
400 kVA
/3601 kW
500 kVA
/4501 kW
500 kVA
/400 kW
625 kVA
/5621 kW
625 kVA
/500 kW
Input voltage  volts  400 400  400  400 400 400 400 400 400 400
Output Voltage  volts  400  400  400  400 400 400 400 400 400 400
Input Voltage Range
 Minimum  volts  340  340  340  340 340  340  340  340  340  340
 Maximum  volts  440  440  440  440  440  440  440  440  440  440
Input /Output Frequency  Hz 50/60 50/60  50/60  50/60  50/60  50/60  50/60  50/60  50/60  50/60
AC Input (with input filter)
 Nominal Amps  amps  254  318  381 429 508 572 728 704 910 880
 Maximum Amps2  amps  317 397  476 536 635 715 910 880 1138 1100
AC Input (without input filter)
 Nominal Amps  amps  288  374  448  490 598 640 792 704 893 880
 Maximum Amps2  amps  360  467  560 613  747 800 910 880 1138 1100
Bypass Input
 Nominal Amps  amps  290  360  433  433 577 577 722 722 902 902
AC Output2
 Nominal Amps  amps  290 360  433  433 577 577 722 722 902 902
 10 Minutes Max.  amps  363  450  541  541 721  721  902 902  432 432
DC Link
 Nominal DC Voltage  volts  420  420   420  420  420  420  384  384  384  384
 Float Voltage  volts  473  473  473  473  473  473  432  432  432  432
 End of Discharge  volts  351  351  351  351  351  351  320  320  320  320
 Maximum Amps  amps  457  571  686  772  914  1030  910  880  1542  1100
System Efficiencies (typical)
 100% Load  %  93  93  93.5  93.5  94  94  93  94  93  94
 75% Load   %  93  93  93.5  93.5  94  94  93  94  93  94
 50% Load   %  92  93  92.5  92.5  93  92.5  93  93  93  93
Full Load Heat Dissipation
 BTU/Hr. (x1000)   41.1  51.4  71.7  81  95.8 107.9  115.7  87.2  144.6  109
 KW   10.4 13  18.1  20.4  24.1 27.2  33.9  25.5  42.4  31.9
Inverter Efficiency (full load)   %  95 95  93.5  93.5  94  94  95  95  95  95

1 Optional 0.9 output p.f.
2 Maximum amps equals full load current plus battery recharge current. Shipping pallet and packaging adds 50 to 300 lbs. per shipping unit

 

 

 

 